PG-2V200
ABS Plastic Rated to UL94:HB
Specifications
- Product Type Title: Rechargeable Sealed Lead Acid Battery
- Product Group Title: PG 2V Series – 2V Long Life
- Product Group: PG 2V Series
- Product Group Marketing Paragraph: Utilizing a special grid alloy and high purity raw materials Power Sonic’s PG 2V series ensures less gassing and reduced self-discharge resulting in a highly dependable long life battery. With proven AGM technology and a thick plate design the PG 2V series have been developed to provide a long service life in critical standby power applications including telecommunications, network communications and military power systems.
- Long Term Storage Statement: PG 2V series batteries may be stored for up to 6 months at 25C (77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter
- Operating Temperature Range - Charge: 5°F (-15°C) to 104°F (40°C)
- Operating Temperature Range - Discharge: -4°F (-20°C) to 122°F (50°C)
- Dimensional Tolerances: +/- 0.04 in. (+/- 1mm) for length and width +/- 0.08 in. (+/- 2mm) for height dimensions
- Additional Specifications: For the detailed technical specifications please refer to the model's technical document
- Group Description: Introducing our high-performance VRLA battery, designed for demanding UPS and telecom applications. With its exceptional capacity, long service life, and advanced AGM technology, our battery delivers reliable power when you need it most. The special grid alloy and high purity lead provide superior shelf-life characteristics, allowing for extended storage periods. Plus, its thick plate design and efficient gas recombination ensure a remarkable lifespan of up to 15 years. Our battery features proven valve regulated technology for safe operation without maintenance. It comes in a rugged impact-resistant ABS case and cover, available in UL94:V0 flame retardant material for ultimate durability and safety. Experience the power and reliability of our VRLA battery, providing uninterrupted performance for your critical equipment. Trust in our solution to deliver consistent, long-lasting power, ensuring smooth and efficient operation.
- Product Description: The PG-2V200 is part of our Rechargeable Sealed Lead Acid Battery range of PG 2V Series often referred to as SLA or VRLA (Valve Regulated Lead Acid) are designed with AGM Technology, Off Grid Capacity, SLA ABS Case, SLA Discharge Recovery, SLA Maintenance Free, and Thick Plate 10-12yr Design Life within critical standby power applications that require a longer design life. The 2V 212.0A battery offers reliable performance in a wide range of applications including Emergency Lighting, Fire Security, Solar, Telecomm, UPS, Utility, and Wind. All Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure consistency and reliability.
- Charging Description: Cycle Applications: Apply constant voltage charge at 2.35VPC – 2.45VPC (14.1 to 14.7 volts for 12V Monobloc) at 20°C. The initial charging current should be set at less than C/5 Amps. Switch to float charge when the current falls to a 3% capacity rate to avoid overcharging.
Stand-By or "Float" Service: Apply constant voltage charge of 2.25VPC – 2.30VPC (13.5 to 13.8 volts for 12V Monobloc) at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition.
Temperature Compensation: Charging voltage for both cyclic and stand-by applications should be regulated in relation to ambient temperature. As temperature rises, charging voltage should be reduced to prevent overcharge and increased as the temperature falls to avoid undercharge.
For further charging information, including temperature compensation factors, see the Power-Sonic Technical Manual.
- Voltage: 2
- Number of Series Cells: 1
- Recommended Charge Current (A): 21.2 - 70.7
- Stored Energy (Wh): 424
- Rated Capacity - 20hr: 212.0
- Rated Capacity - 10hr: 200.0
- Rated Capacity - 5hr: 175.0
- Rated Capacity - 1hr: 122.7
- Capacity Voltage - 20hr: 1.75
- Capacity Voltage - 10hr: 1.75
- Capacity Current - 10hr: 20.00
- Capacity Voltage - 5hr: 1.70
- Capacity Voltage - 1hr: 1.60
- Cycle Constant Voltage Range: 2.33V - 2.45V
- Float Constant Voltage Range: 2.25V - 2.30V
- Initial Charging Current (A): 53.00
- Life Expectancy: 15 years in standby
- Capacity Current - 5hr: 35.00
- Capacity Current - 1hr: 122.70
- Max Discharge Current (A): 1600
- Internal Resistance (mΩ): 0.9
- Capacity Current - 20hr: 10.60
- Max Continuous Discharge Current (A): 1,600
- Case: ABS Plastic Rated to UL94:HB
-
Image Featured:
- Minimum Weight (kg): 13.50
- Minimum Weight (lbs): 29.76
- Length (in): 6.69
- Length (mm): 170
- Width (in): 4.33
- Width (mm): 110
- Height (in): 13.70
- Height (mm): 348
- Height Over Terminal (in): 13.70
- Height Over Terminal (mm): 348
-
Dimensions Image:
- ISO9001:2015 - International standard that specifies requirements for a quality management system (QMS)
- Prop65 - Compliance required providing warnings to Californians about significant exposures to chemicals that cause cancer, birth defects or other reproductive harm
- SLA Transport - Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B., and certified by Department of Transportation regulations that include hazardous materials transportation regulations and federal motor carrier regulations
- UL 1989 - These requirements cover valve regulated or vented batteries that can be used as instrument batteries, enclosed batteries, emergency lighting and power batteries and uninterruptible power supply batteries
- UL Recognized - Rigorous safety testing ensuring the safety and efficiency of machinery used by workers
- AGM Technology - Absorbent Glass Mat (AGM) technology for superior performance, service life, and reliability
- Off Grid Capacity - Wide offering of capacity range ideal for large capacity off-grid systems
- SLA ABS Case - Rugged vibration and impact resistant ABS case and cover
- SLA Discharge Recovery - Excellent recovery from over discharge situations
- SLA Maintenance Free - Proven valve regulated technology that guarantees safe operation without maintenance or refilling
- Thick Plate 10-12yr Design Life - Thick plate design and efficient gas recombination yield a service life of 10 – 12 years in standby mode