PS-12380

ABS Plastic Rated to UL94:HB

Specifications

  • Product Type Title: Rechargeable Sealed Lead Acid Battery
  • Product Group Title: PS Series – General Purpose
  • Product Group: PS Series
  • Product Group Marketing Paragraph: Power Sonic PS series of sealed lead acid batteries have been designed with AGM (Absorbent Glass Mat) technology to ensure superior performance and reliability. The PS series has been specifically engineered for use in general purpose float and light cyclic applications including fire and security systems, emergency lighting, UPS, toys and medical devices.
  • Long Term Storage Statement: PS series batteries may be stored for up to 6 months at 25C (77 F) and then a freshening charge is required. For higher temperatures the time interval will be shorter
  • Operating Temperature Range - Charge: 5°F (-15°C) to 104°F (40°C)
  • Operating Temperature Range - Discharge: -4°F (-20°C) to 122°F (50°C)
  • Dimensional Tolerances: +/- 0.04 in. (+/- 1mm) for length and width +/- 0.08 in. (+/- 2mm) for height dimensions
  • Additional Specifications: For the detailed technical specifications please refer to the model's technical document
  • Group Description: Power Sonic's PS series of sealed lead acid batteries are designed with AGM technology to provide superior performance and reliability for general purpose float and light cyclic applications. This series is perfect for fire and security systems, emergency lighting, UPS, toys, and medical devices. For heavy-duty applications like pitch control, braking, and renewable energy, the PS HD series of rechargeable lead acid batteries with increased vibration resistance is an ideal choice. Several batteries from our PS range are VdS approved, ensuring their quality for use in fire, security, and life safety applications. As one of the world's leading inspection and certification companies in the fire protection and security industry, VdS sets international standards and guidelines for fire protection and safety equipment. We have over 50 years of extensive experience in developing and supplying batteries for various applications, and our team of experts can provide the right battery technology to meet your technical demands. We offer a wide range of 2v, 4v, 6v, and 12v AGM batteries with capacities ranging from 0.5ah to 260ah to cater to your power requirements. All Power Sonic batteries undergo strict quality control measures throughout the manufacturing process to ensure consistency and reliability.
  • Product Description: The PS-12380 is part of our Rechargeable Sealed Lead Acid Battery range of PS Series often referred to as SLA or VRLA (Valve Regulated Lead Acid) are designed with AGM Technology, Gas Recombination, Power Volume Ratio, SLA ABS Case, and SLA Maintenance Free within general purpose and standby applications. The 12V 40.0A battery offers superior performance in a wide range of applications including Emergency Lighting, Fire Security, General Purpose, Medical, Solar, Telecomm, UPS, Utility, and Wind. All Power-Sonic batteries are subject to stringent quality controls through each step of the manufacturing process to ensure consistency and reliability.
  • Charging Description: Cycle Applications: Apply constant voltage charge at 2.35VPC – 2.45VPC (14.1 to 14.7 volts for 12V Monobloc) at 20°C. The initial charging current should be set at less than C/5 Amps. Switch to float charge when the current falls to a 3% capacity rate to avoid overcharging. Stand-By or "Float" Service: Apply constant voltage charge of 2.25VPC – 2.30VPC (13.5 to 13.8 volts for 12V Monobloc) at 20°C. When held at this voltage, the battery will seek its own current level and maintain itself in a fully charged condition. Temperature Compensation: Charging voltage for both cyclic and stand-by applications should be regulated in relation to ambient temperature. As temperature rises, charging voltage should be reduced to prevent overcharge and increased as the temperature falls to avoid undercharge. For further charging information, including temperature compensation factors, see the Power-Sonic Technical Manual.
  • Voltage: 12
  • Number of Series Cells: 6
  • Recommended Charge Current (A): 4.0 - 13.3
  • Stored Energy (Wh): 480
  • Rated Capacity - 20hr: 40.0
  • Rated Capacity - 10hr: 38.0
  • Rated Capacity - 5hr: 32.6
  • Rated Capacity - 1hr: 24.0
  • Capacity Voltage - 20hr: 10.50
  • Capacity Voltage - 10hr: 10.50
  • Capacity Current - 10hr: 3.61
  • Capacity Voltage - 5hr: 10.20
  • Capacity Voltage - 1hr: 9.60
  • Cycle Constant Voltage Range: 14.00V – 14.70V
  • Float Constant Voltage Range: 13.50V - 13.80V
  • Initial Charging Current (A): 3.80
  • Life Expectancy: 10-12 years in standby
  • Capacity Current - 5hr: 6.22
  • Capacity Current - 1hr: 22.00
  • Max Discharge Current (A): 380
  • Internal Resistance (mΩ): 10
  • Capacity Current - 20hr: 1.90
  • Max Continuous Discharge Current (A): 380
  • Recommended Chargers: PSC-122000ACX
  • Case: ABS Plastic Rated to UL94:HB
  • Image Featured:
  • Minimum Weight (kg): 12.70
  • Minimum Weight (lbs): 28.00
  • Length (in): 7.76
  • Length (mm): 197
  • Width (in): 6.50
  • Width (mm): 165
  • Height (in): 6.69
  • Height (mm): 170
  • Height Over Terminal (in): 6.85
  • Height Over Terminal (mm): 174
  • Dimensions Image:
  • CE - Indicates that a product has been assessed by the manufacturer and deemed to meet EU safety, health and environmental protection requirements
  • IEC60896 - Compliant with IEC standard applying to all stationary lead-acid cells and monobloc batteries of the valve regulated type for float charge applications
  • ISO9001:2015 - International standard that specifies requirements for a quality management system (QMS)
  • Prop65 - Compliance required providing warnings to Californians about significant exposures to chemicals that cause cancer, birth defects or other reproductive harm
  • SLA Transport - Approved for transport by air. D.O.T., I.A.T.A., F.A.A. and C.A.B., and certified by Department of Transportation regulations that include hazardous materials transportation regulations and federal motor carrier regulations
  • UL 1989 - These requirements cover valve regulated or vented batteries that can be used as instrument batteries, enclosed batteries, emergency lighting and power batteries and uninterruptible power supply batteries
  • UL Recognized - Rigorous safety testing ensuring the safety and efficiency of machinery used by workers
  • VdS - Tests capacity for security products and assigns them to classes which are used by insurance companies and the police
  • AGM Technology - Absorbent Glass Mat (AGM) technology for superior performance, service life, and reliability
  • Gas Recombination - Gas recombination technology for quick recovery of capacity during charge
  • Power Volume Ratio - Excellent power to volume ratio yielding high energy density
  • SLA ABS Case - Rugged vibration and impact resistant ABS case and cover
  • SLA Maintenance Free - Proven valve regulated technology that guarantees safe operation without maintenance or refilling